PRODUCT DESCRIPTION

It is used for insulation of very high temperatures, industrial facilities, process equipment, steel construction structures, all kinds of technical details requiring heat insulation and fire safety.

APPLICATION AREAS

It is used for heat, sound and fire insulation in steel constructions, industrial plants, process equipment.

APPLICATION PRINCIPLES

Application surfaces; After the insulation is made ready for the coating by means of hanging pins or carrier hoops, the plates are installed and the sheet metal coatings are made. It is also used in ready panel applications of industrial plates.

Technical Table

All our products are adaptable and can be customised on request in density, thickness, size and coating with a minimum order.
 

Density

Thickness

Size
(mm x mm)

In-Pack
Pieces

m²/
Package

70

30

600 x 1200

15

10.80

1.666

2.833

70

40

600 x 1200

12

8.64

1.250

2.125

70

50

600 x 1200

8

5.76

1.000

1.700

70

60

600 x 1200

6

4.32

833

1.416

70

70

600 x 1200

6

4.32

715

1.214

70

80

600 x 1200

5

3.60

625

1.063

70

100

600 x 1200

4

2.88

500

850

70

120

600 x 1200

4

2.88

416

700

100

30

600 x 1200

8

5.76

1.666

2.833

100

40

600 x 1200

6

4.32

1.250

2.125

100

50

600 x 1200

4

2.88

1.000

1.700

100

60

600 x 1200

4

2.88

833

1.416

100

70

600 x 1200

3

2.16

715

1.214

100

80

600 x 1200

4

2.88

625

1.063

100

100

600 x 1200

3

2.16

500

850

100

120

600 x 1200

2

1.44

416

700

110

25

600 x 1200

10

7.20

2.000

3.400

110

30

600 x 1200

8

5.76

1.666

2.833

110

40

600 x 1200

6

4.32

1.250

2.125

110

50

600 x 1200

4

2.88

1.000

1.700

110

60

600 x 1200

4

2.88

833

1.416

110

70

600 x 1200

4

2.88

715

1.214

110

80

600 x 1200

4

2.88

625

1.063

110

100

600 x 1200

3

2.16

500

850

110

120

600 x 1200

2

1.44

416

700

Reminders on Loading, Unloading, Transport and Storage:
 
• It should be done in closed areas in rainy weather.
• Stretch the canvas even when hey are shipped for short distances
• It should be stored in the package and the damaged package should not be used.
• Packages should not be stacked on top of each other
• The products are not be stepped on or used as a step.
• Before pulling with rope, hard cardboard with dimensions of 50x20 cm size should be placed under the rope.
• Storage area should be closed to prevent leakage during rain, flooding etc.
• The storage floor must be flat and non-slippery
• Loading and unloading should be done with the roof crane.
• Plates should be carefully transported to the application area by two persons.
• Before pulling the rope, 50x20 cm hard cardboard should be placed under the rope.
• The storage floor must be flat and non-slippery